Towards Rapid & Autonomous Preclinical Discovery

Steven Cao*, Melissa Du*, Elizabeth Zhang, Bo Hu, Ivan Hernandez, Di Hu, Jonah Kim, Erica Seigneur, Nicolas Pellier, Alana Pickett, Gio Carosso, Suman Machinani, Helena Rose, Isaak Freeman
* Equal contribution.

The mission of Capable is to develop therapeutics that enhance human capabilities. To achieve this goal, we're building a full-stack lab for preclinical drug discovery, starting with peptides.

Developing a drug from target selection to an IND-enabling candidate usually takes 4.5 years of iteration across thousands of candidate molecules. In the past six months, we have made and tested hundreds of compounds and are on track to scale up to 1,000 compounds a month, which will enable us to produce a lead candidate in months instead of years. This rapid acceleration has been achieved through vertical integration and lab automation.

We largely design, synthesize, and test on cells and animals in-house, then use the results to design the next generation. This enables us to achieve close to an order-of-magnitude speedup compared to the industry-standard path of CROs. At the same time, we are automating each step in the discovery loop to scale the capacity of our small human team. Our agent now designs a majority of candidates and is starting to run our physical lab, controlling the instruments and training specialized models to improve method development.

We're sharing more of our early progress below.

Vertical Integration

Pharma companies currently outsource a third of their discovery and preclinical work, and the percentage is increasing. Using external vendors slows every step. CROs serve many clients with limited capacity. Compounds may need to be shipped across countries from one lab to the next. Developing new cell lines or breeding transgenic mouse strains can add months, and sometimes fails entirely.

At Capable, much of our synthesis, purification, cell assays, and mouse studies happens under the same roof. This enables lead optimization to be compressed down to the physical time that each step takes.

In our first lab, we were reliably getting 6–8 compounds from synthesis to mouse data every 24 hours, with 4.5 hours typically spent on automated synthesis, 10.5 hours on cleavage, purification, and evaporation, 1 hour in QC, 4 hours in cells, and 4 hours for initial mouse readouts.

Bar chart of days from synthesis to cell data, each bar split into synthesis and purification, and cell assay. Industry: median 35 days (24 and 11), best 21 days (14 and 7). Capable: median 4.5 days (about 1.5 and 3), best 6 hours.
Capable vs. CRO turnaround times, median and best.* Industry: the midpoint and the fastest of the vendor quotes we received, excluding contracting and assay setup. The fastest, 21 days, is the best we have found for custom drug-like molecule synthesis and cell testing after an extensive search.† Capable: median step times in our lab, September to November 2026. Our fastest run took 6 hours from design through synthesis, purification, quality control, and first cell data.

Now at the new lab, we're in the process of scaling our capacity by 30x using slower but higher-throughput methods. Our parallelized synthesis setup produces 200 compounds in 24–48 hours, and we're working to scale our purification accordingly. The average turnaround time in the new lab has been 4.5 days to get cell data, with mouse readouts taking on average one extra day. This is an ~8x speedup compared to CROs, who have previously quoted us 24 days for synthesis and 11 days for cell assays.

Loop Automation

Vertical integration provided us with massive efficiency gains, but to scale our compound capacity, we are increasingly turning to automation.

Automated platforms have already been built for most of the lead optimization pipeline. Liquid-handling robots have existed since the 1980s and are commoditized by vendors like Hamilton. Parallel synthesizers can make hundreds of compounds at a time, and high-throughput screeners can test thousands a day.

However, each step remains bottlenecked by skilled human researchers. We attribute this to three challenges of increasing difficulty:

  1. Operation: The first-party software on many of these instruments is often poorly designed and tedious to use. Researchers sometimes have to type in the details of every single input by hand.
  2. Method development: There isn't a single method that generalizes to every experiment on a machine, and it's often difficult to predict optimal conditions a priori. Researchers with years of experience refine these parameters through trial and error.
  3. Physical work: Even if current instruments were fully automated, they would still need a researcher to prepare and load the physical materials, and hand them off between instruments.

We are progressing through these challenges in order: having agents first take over instrument operation, then method development, and finally all physical work.

Four stages of lab automation. Stage 0: researchers run the entire discovery loop and at most ask agents for advice. Stage 1: agents operate the instrument software, while researchers develop the methods and do the physical work. Stage 2: agents refine the methods themselves and researchers only do the physical work. Stage 3: robotics lets agents run the entire loop while researchers oversee them.
Progression of lab automation.

Many companies in this space are working to improve model intelligence and robotics in the lab. But we believe the largest bottleneck today is integration. Apart from a few tasks that still need new capabilities, like animal handling, we can automate the full lead optimization loop from design to testing by connecting existing models, instruments, and robots.

Much of our lab operates at Stage 1, where agents operate the instruments, and we're now building towards Stage 2, where they also develop the methods. Lab automation is driven by our in-house agent, Iris. We reverse-engineered legacy software to give Iris access to our instruments, experimental results, and physical inventory. Across our discovery loop, these efforts have enabled us to rapidly scale the number of molecules that we make and test.

Column chart of molecules per month in 2026. Molecules tested in vivo and in vitro rise each month from August to October; molecules made dip slightly in September, then reach about 290 in October.
Molecules made, tested in vitro, and tested in vivo at our new lab. September's in vitro testing includes externally contracted synthesis services, which typically take 4–6 weeks.

1. Synthesis

Our high-throughput synthesizers build a large number of peptides in parallel. A robotic pipette retrieves the amino acids and other reagents needed each cycle and dispenses them across a plate of reaction vessels.

Solid-phase peptide synthesis

We make our molecules using solid-phase peptide synthesis (SPPS) rather than the DNA-based methods used to automate protein production. SPPS builds peptides one amino acid at a time on beads of resin. A cycle has four steps:

The solid-phase peptide synthesis cycle, repeated for each amino acid: 1. Deprotect: a base strips the cap off each chain. 2. Wash: the vessel is rinsed of the base and loose caps. 3. Couple: the next capped amino acid is added and bonds to the chain. 4. Wash: the vessel is rinsed of leftover amino acids.
The solid-phase peptide synthesis cycle.

SPPS lets us create short peptides that make extensive use of noncanonical amino acids, which are key to drug design because they make it easier to achieve desired potency and stability. Common examples include D-amino acids, beta-homo amino acids, cyclization handles, and lipidated side chains.

The blockbuster drug tirzepatide wouldn't have been possible without the noncanonical aminoisobutyric acid (Aib) that protects it from rapid deactivation, or the long diacid lipid tail at position 20. One of our lead molecules may end up more than 80 percent noncanonical.

Iris helps set up each run. It takes a list of peptide sequences, determines what inputs are needed, checks them against inventory, and provides the researcher with instructions for what to load onto the machine. This setup lets the same small team operate more machines in parallel. In the past six weeks, we've gone from two synthesizers to six and increased our maximum production capacity by 40x.

We're now working to achieve reliable throughput across all classes of peptides by having Iris plan our method development based on the purification results achieved across existing compound series and methods. This matters especially for difficult structures like macrocycles, where a researcher needs to iterate multiple times to find the best synthesis conditions.

2. Purification

Synthesis does not yield a pure product. Samples contain the target peptide alongside chemical impurities. When a coupling fails, an amino acid is skipped, leaving a deletion sequence. Chains that stop growing early leave truncations. Others retain side-chain protecting groups that cleavage failed to remove. We separate the target peptide from these impurities using reverse-phase chromatography.

Reverse-phase chromatography

The sample is pumped through a column while the solvent gradually becomes more organic over time. Each peptide comes off the column, or elutes, at its own characteristic point in that gradient and appears as a peak on a UV detector.

Illustration of a chromatography run: organic solvent (%B) rises linearly over time, and three peaks appear on the UV detector, the middle one our product, each at the point in the gradient where that peptide elutes.
Illustration of a chromatography run.

To separate neighboring peaks of compounds cleanly, you need to slowly ramp up the percentage of organic solvent (% B). However, this takes a relatively long time unless you can narrow down the elution range.

We then quantify purity using liquid chromatography–mass spectrometry (LC-MS). Characterizing the synthesis byproducts using existing analytical tools is an incredibly time-consuming task, but now Iris runs this process fully autonomously.

This is another area where we've started integrating Iris into method development. A researcher typically starts with a "scouting" run to identify roughly when the target peptide comes off the column. Iris trained a model on our past purification runs to predict this property directly from the peptide's chemical structure and SAR, achieving an average error of 3% B in testing.

3. In Vitro Testing

Purified peptides then move on to cell testing to characterize their functional activity. Researchers previously spent hours at the bench pipetting compounds into the plates by hand.

Potency cell assays

For measuring potency, we maintain cell lines that overexpress target proteins and dose them with each peptide across a range of concentrations. When a peptide activates the receptor, the cells produce a quantifiable molecular signal that we measure on a plate reader. We then fit a dose-response curve for each peptide to determine its potency.

Dose-response curves for a reference peptide and a potent, a weak and an inactive analogue: receptor response against peptide dose on a log scale, with dotted lines marking where each curve reaches half of its maximum response. The potent analogue reaches it at a lower dose than the reference, the weak analogue at a much higher dose, and the inactive analogue stays flat.
Dose-response curves from a real cell assay. Each dot represents one well. Peptide identities and concentrations are withheld.

We built our automated cell screening setup by reverse-engineering the software on our high-throughput liquid handlers. A researcher now prepares the cells and peptides, loads them onto the machine, and then directs Iris to run the screening. After the plates are read, Iris verifies each plate's quality against prior runs, then determines each peptide's dose-response curve relative to a reference peptide.

This automated setup lets us scale our cell assay capacity while also improving quality compared to purely human-led assays. Within two weeks of our first automated run, a single researcher can now test 100 compounds instead of 30 in 3 hours. Over the same period, the variation between duplicate wells given the same dose fell from about 6 percent to 1.5 percent.

Two charts from September to November. Top: compound curves per week, under 50 a week when manual and up to about 140 a week once automated. Bottom: duplicate CV, about 6 percent in manual runs and about 1.5 percent in automated runs.
Cell assay throughput and precision before and after automation. Top: peptide dose-response curves tested per week. Bottom: median variation between duplicate wells in each run.

4. In Vivo Testing

We then test our most promising peptides in mice. A typical study compares several dose groups against a placebo group. For our sleep program, we measure how long a mouse remains awake after a dose and its sleep patterns over time.

Animal testing for clinical trials

Before a drug can enter human testing, the FDA requires nonclinical safety data in a pharmacologically relevant species, which expresses a version of the target that the peptide binds and exhibits the same downstream biological effect as in humans. Studies often start with mice or rats, which give fast early evidence on pharmacology and safety. Once a lead candidate drug has been finalized, dog or non-human primate testing follows.

We regularly surgically implant EEG sensors into our mice to track their sleep. This is the gold standard for sleep research, but it is expensive and difficult to scale. Our single specialist can implant ten mice a day at most.

In the past few months, we have collected over 60,000 hours of mouse data in our lab. By extracting features like mouse posture and stillness from video data, Iris trained a specialized model that estimates total daily sleep within 2 percent of EEG recordings. This has been transformative: we can now scale our mouse studies simply by using cages fitted with cameras. In the past two months alone, we have run more than a thousand mice through studies.

Sleep for one mouse over 24 hours from 6 PM, scored from EEG in one row and from our video model in the row below; the two rows' sleep bouts line up closely.
Sleep for one mouse over 24 hours, scored from EEG and our model.

We're also automating readouts for our other programs, some of which need to be recorded over longer timespans. They also require additional infrastructure, such as behavioral mazes to measure cognition or body-composition scanners to track muscle retention. We're working to scale these systems.

Concluding Thoughts

We're working towards a future in which we can design and test a drug preclinically in months instead of years. It will mean a step change in the number of new targets and molecules that we are able to explore.

Clinical trials will remain our largest bottleneck. Moving through Phases I–III takes six to eight years on average and accounts for more than half the cost of bringing a new drug to market. About 90 percent of drugs that enter trials never earn FDA approval.

We're working to cut the time and cost of showing that our drugs are safe and effective. For our sleep program, our first trials are located in Australia, where the regulatory system moves faster and human testing typically starts 6–12 months sooner than in the US. We're also partnering with expert clinical investigators with a track record of getting sleep drugs to FDA approval, and with clinical sites that have existing operational capacity for sleep testing.

There is much to accomplish. Our rapid progress so far has been made by a small, talent-dense team. Our flat structure enables team members across scientific disciplines to work closely together. If you are interested in working with us, we are hiring across chemistry, biology, and engineering.